Ideal solution for both mobile and fixed communication terminals. Designed for high efficiency, resulting in an optimal compact form factor with high performance and reliability. With the advanced customer interface and HTTP embedded web page, the operator is able to monitor and control both BUC and the system redundancy.
Key Features
- DUAL LO = same unit covers both standard and extended Ku-Band
- Extremely compact size
- 1:1 switching logic built into the BUC, eliminating expensive external controller
- Built-in telemetry facilities for critical parameters such as: RF power detection, mute control, over temperature shutdown, summary alarm
- WEB interface and SNMP monitoring
- RS485, RS232, Ethernet and dry-contacts M&C Interface
Redundancy Manager
The 50-250W Ku-Band BUC’s integrate fully with IGP’s advanced content based Redundancy Manager. This Redundancy Manager uses site diversity software with intelligent switching (within one second to an optional amplifier) based on source comparison and multiple receiver info:
Specifications
Electrical Characteristics |
||
Standard Band | Extended Band | |
Output Frequency Range | 14.00 – 14.50 GHz | 13.75 – 14.50 GHz |
Input Frequency Range | 950 – 1450 MHz | 950 – 1700 MHz |
Local Oscillator Frequency | 13.05 GHz | 12.80 GHz |
Gain Stability Over Temperature | ±1.5 dB nominal; ±2.0 dB max | ±1.5 dB nominal; ±2.25 dB max |
Gain Variation at fixed temperature | ±0.5 dB over max over 36 MHz; ±2.0 dB over full band | ±0.75 dB over max over 36 MHz; ±2.25 dB over full band |
Linear Gain | 70 dB min. | |
User Adjustable Gain | 20 dB in 0.5 dB steps | |
Intermodulation | -25 dBc, with 2 equal carriers at 3dB total power back off from rated power (PSAT -3dB) | |
10MHz Reference | 0dBm ± 5.0 dB – External via IF / (Internal 10MHz reference optional) |
@ 100 Hz | @ 1 kHz | @ 10 kHz | @ 100 kHz | @ 1 MHz | |
Phase Noise Requirement | -140 dBc/Hz max | -150 dBc/Hz max | -155 dBc/Hz max | ||
Local Oscillator Phase Noise | -63 dBc/Hz max | -73 dBc/Hz max | -83 dBc/Hz max | -93 dBc/Hz max | |
Output Spurious | -55 dBc max @PLinear | ||||
Harmonics | -50 dBc max @PLinear | ||||
VSWR | Input (1:50:1) Output (1:20:1) |
Interface |
||||
Power | M&C (RS232/485/Ethernet) | RF Sample | Redundancy | |
Connectors | MS Connector | MS Connector | N-Type Female (optional) | MS Connector |
Output Interface | Waveguide, WR75G (Grooved) | |||
Input Interface | N-Type Female, 50 Ohms, F-Type Female, 75 Ohms (optional) |
Environmental |
||
Temperature Range (ambient) | Humidity | Altitude |
-40°C to + 55°C (operating); -40°C to + 75°C (storage) | 0 to 100% (condensing) | 10,000 ft ASL |
Specification by BUC Power |
|||||
BUC power PSAT (typical) Watts | Output Power @P1dB (dBm) | Power Requirement | Power Consumption (Watts) | Dimensions (in/cm) | Weight (lbs/kg) |
50 W | +46 | 110 – 220 VAC (*1) | 450 | 12.8 x 8.2 x 7.1 / 32.5 x 20.8 x 18.0 | 27.8 / 12.5 |
60 W | +47 | 110 – 220 VAC (*1) | 500 | 12.8 x 8.2 x 7.1 / 32.5 x 20.8 x 18.0 | 27.8 / 12.5 |
80 W | +48 | 220 VAC | 850 | 16.0 x 16.9 x 5.2 / 41.0 x 43.0 x 13.2 | 47.5 / 21.6 |
100 W | +49 | 220VAC | 1000 | 16.0 x 16.9 x 5.2 / 41.0 x 43.0 x 13.2 | 47.5 / 21.6 |
125 W | +50 | 220 VAC | 1200 | 16.0 x 16.9 x 5.2 / 41.0 x 43.0 x 13.2 | 47.5 / 21.6 |
200 W | +52 | 220 VAC | 2500 | 16.9 x 24.5 x 9.2 / 43.0 x 62.2 x 23.4 | 94.1 / 42.8 |
250 W | +53 | 220 VAC | 2600 | 16.9 x 24.5 x 9.2 / 43.0 x 62.2 x 23.4 | 94.1 / 42.8 |